LMTK balanced flowmeter

The design principle of LMTK balance flowmeter is based on Bernoulli's law of conservation of energy, using a specially optimized porous disk throttling rectifier sensor (balance flow sensor)

product details

The advantages of LMTK balanced flowmeter:


● High measurement accuracy


The uncertainty of the outflow coefficient in instrument design is ± 0.5%


DN15~500 instrument calibration before leaving the factory


Commissioned third-party calibration for DN500 and above


Low requirements for straight pipe sections


The optimal configuration is 5D in the front and 5D in the back


Normal configuration with 2D before and 2D after


0.5D before and 0.5D after the minimum configuration


Low permanent pressure loss


The maximum permanent pressure loss is about 1/3 to 1/4 of the maximum differential pressure, with low flow noise and fast pressure recovery.


● Wide range ratio


The normal range ratio for use is 10:1


The maximum usage range ratio is 15~25:1


Note: The maximum usage depends on the working conditions and the differential pressure gauge used in conjunction


Good repeatability and long-term stability


Instrument repeatability ≤ 0.1%


Right angle and through-hole design, wear-resistant


The flow field distribution is uniform, and the deviation of the outflow coefficient is small after long-term use


● Resistant to dirt and easy to block


Reduced the formation of eddy currents and dead zones, allowing dirty media to pass through the throttle hole,


Reduce the impact of the accumulation of dirty media on flow measurement


● Wide applicability


The β value can be selected from 0.25 to 0.90


Reynolds number 200-107


Size DN15-3000


Almost all working conditions


Low temperature fluids and liquid gases


Can directly measure bidirectional flow


● Can be used for bidirectional measurement


The throttling element is designed as a symmetrical structure with flat, plate, and straight through holes, and the pressure tapping hole is located at the flange pressure tapping position. With the corresponding differential pressure gauge, it can achieve bidirectional flow measurement with one flowmeter without changing the installation method.


● Easy to install, use, and maintain


The LMTK balanced flowmeter is a differential pressure flowmeter, and its installation, use, and maintenance are completely consistent with standard throttling devices (orifice plate, nozzle, and Venturi).


● Powerful selection calculation software and physical property database


The perfect combination of ISO5167 flow equation and powerful physical property database.


The software's built-in physical property database contains over 1700 types of media, covering almost all measurable media in the chemical industry.